Title |
A Study in The Efficiency Improvement of Thermal Plasma Gas Processor Through Fluid Dynamics Analysis of Reaction Zone |
Authors |
서문준(SeoMun, Jun) ; 정진도(Chung, Jin-Do) ; 구경완(Koo, Kyung-Wan) |
DOI |
https://doi.org/10.5370/KIEE.2011.60.3.669 |
Keywords |
Arc plasma ; Temperature distribution ; Flow pattern |
Abstract |
This study explores the numerical analysis method of fluid dynamics in the reaction section to improve the gas processing efficiency in the hazardous gas removal by atmospheric thermal plasma. This study also intends to contribute in technology advance to improve the processing efficiency and make the process more stable. Numerical analysis of temperature distribution in the reaction section dependent on the change in flow velocity of Ar and plasma temperature change, which are major control variables in the cracking process of HFC-23 using arc plasma, was done. The characteristic of incoming oxygen by temperature suggested that when temperature increased to 1600K, 1700K, 1800K respectively, the range of cracking temperature 1500K increased to 75.0%, 83.3%, 90.2% respectively. The temperature change of Ar by velocity change was widest in the area higher than 1500K when the velocity was 2.5m/s; however, since there was no big difference when the velocity was 2m/s, it is believed that 2 m/s would be most proper. |