Title |
Design of Erase Waveform for Stabilizing Reset Discharge in Mid-gap AC Plasma Display Panels |
Authors |
윤수한(Yoon, Su-Han) ; 서정현(Seo, Jeong-Hyun) |
DOI |
https://doi.org/10.5370/KIEE.2011.60.5.993 |
Keywords |
Mid-gap ; Discharge ; Reset ; Plasma display |
Abstract |
In this paper we suggest new criteria for the classification of the electrode gap between common and scan electrodes. The electrode gap is categorized as a short, middle, and long gap according to the criteria. Among these structures, we focus on the erase waveform of a mid-gap structure. we report an unstable discharge arising from the erase ramp period in a mid-gap structure. Based on the Vt close curve, we analyze the unstable discharge at various conditions. Our analysis reveals that the unstable discharge is ignited between surface electrodes and caused by un-erased wall charges accumulated on the outer edges of electrodes. By reducing the voltage level of the last sustain pulse, the problem is solved. |