Title A Study About the Application Feasibility of EMS IEC 61000-4-6 Test Standard on Electronic Power Meter
Authors 김석곤(Kim, Seok-Gon) ; 박창호(Park, Chang-Ho) ; 신동열(Shin, Dong-Yeol) ; 송태승(Song, Tae-Seung) ; 최용성(Choi, Yong-Sung)
DOI https://doi.org/10.5370/KIEE.2011.60.6.1261
Page pp.1261-1267
ISSN 1975-8359
Keywords Electronic power meter ; EMC ; EMS ; EMI ; Immunity ; Susceptibility ; Radio frequency ; Harmonics
Abstract Electricity meters using in Korea are about 1.8 million units. From among these, electronic meters for high voltage, about 170 thousand units were installed to the digital type meter and ones for low voltage installed hundreds of thou-sands of meters through a model project. Recently, low voltage meter are expected to complete the installation within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Accordingly, it is important to ensure an immunity of meter for electromagnetic field and environmental noise at the installation site. In this paper, we are going to check the validity of international standard that focusing on RF electromagnetic field immunity of meter to secure the quality and improve the reliability in field operation of meter. And we will verify the validity of test specification focused on actual installation environment and are going to offer the improvement plan of test standard.