Title Study on Distortion Ratio Calculation of Park's Vector Pattern for Diagnosis of Stator Winding Fault of Induction Motor
Authors 양철오(Yang, Chul-Oh) ; 박규남(Park, Kyu-Nam) ; 송명현(Song, Myung-Hyun)
DOI https://doi.org/10.5370/KIEE.2012.61.4.643
Page pp.643-649
ISSN 1975-8359
Keywords Distortion ratio calculation ; Induction motor ; Diagnosis ; Stator winding fault ; Park's vector
Abstract The diagnosis technique of stator winding faults based on Motor Current Signature Analysis(MCSA) was suggested. Park's vector pattern, the circle that is drawn by d-q transformed currents(i_d, i_q), is widely used for stator winding faults detection. The current Distortion Ratio(DR), defined by the ratio of max axis and min axis of ellipse of Park's vector's pattern, was more simple and powerful method than the Park's vector pattern. In this study, a calculation method of distortion ratio of Park's vector pattern was suggested for auto diagnosis of stator winding short fault and usefulness of suggested calculation method of distortion ratio was verified through simulation using LabVIEW program.