Title |
Monitoring Performance of Camera under the High Dose-rate Gamma Ray Environment |
Authors |
조재완(Cho, Jai-Wan) ; 정경민(Jeong, Kyung-Min) |
DOI |
https://doi.org/10.5370/KIEE.2012.61.8.1172 |
Keywords |
High dose-rate gamma ray ; Fukushima nuclear power plant ; Speckle ; Packbot |
Abstract |
In this paper, the gamma ray irradiation test results of the CCD cameras are described. From the low dose-rate (2.11 Gy/h) to the high dose-rate (150 Gy/h) level, which is the same level when the hydrogen explosion was occurred in the 1~3 reactor unit of the Fukushima nuclear power plant, the monitoring performance of the cameras owing to the speckles are evaluated. The numbers of speckles, generated by gamma ray irradiation, in the image of cameras are calculated by image processing technique. And the legibility of the sensor indicator (dosimeter) owing to the numbers of the speckles is presented. |