Title |
High Efficacy Plasma Display Utilizing Macro Discharge Cell Structure with Long Electrodes Gap |
Authors |
김민태(Kim, Min-Tae) ; 허준(Heo, Jun) ; 김윤기(Kim, Yun-Gi) ; 김동현(Kim, Dong-Hyun) ; 이해준(Lee, Hea-June) ; 이호준(Lee, Ho-Jun) |
DOI |
https://doi.org/10.5370/KIEE.2012.61.9.1314 |
Keywords |
AC-PDP ; Macro cell ; Opposite discharge ; High efficacy display ; PID system |
Abstract |
Recently, applications of plasma display to the large public display and transparent display gain much attention. With this background, we report characteristics of opposite electrodes discharge cell with long electrode gap in comparison with conventional co-planar surface discharge. The cell size of test panel is 2950μm×840μm, which corresponds to that of the display having diagonal size of 130" with XGA resolution. Electrode gap of co-planar and opposite electrode structure are 240μm and 500μm respectively. These gap dimensions provide similar driving voltage windows. Experimental results show that opposite discharge provides approximately four fold higher luminous efficacy compared with that of the surface discharge. Resulting efficacy is found to be higher than 19 lm/W in green phosphor with 10 KHz continuous pulse operation. |