Title |
Design of a Guide Vane for Improving Inside Flow Uniformity of Electrostatic Precipitator |
Authors |
노경욱(Noh, Kyung-Wook) ; 배성준(Bae, Seong-Jun) ; 박숙희(Park, Sookhee) ; 강선균(Kang, Sunkyun) ; 이장명(Lee, Jangmyung) |
DOI |
https://doi.org/10.5370/KIEE.2013.62.4.523 |
Keywords |
Guide Vane ; Air Pollution ; Electrostatic Precipitator ; Flow Uniformity |
Abstract |
In recent years, many efforts are increasingly being made to conserve the natural environment with enhanced emission standards and air quality standards. Also there are various methods necessary to be researched to minimize the emission of air pollutants. In particular, boilers of industrial facilities are major portions of the air pollution. The front duct which needs to be designed to reduce the gases to the electrostatic precipitator requires a bent tube, a reduction/extend tube and an auxiliary equipment, that is, a guide vane. This paper proposes an optimum design of the guide vane by a case study for electrostatic precipitator's flow uniformity. The operating conditions of this study are as follows: BMCR (Boiler Maximum Continuous Rate) and MGR (Maximum Guaranteed Rate) are 75%, 50%, and 30%; turbulent fluid dynamics model is based upon K-ε formulation. Presentation of the computed motion of particles is found to be quite useful to predict the precipitator performance by use CFD (Computational Fluid Dynamics). |