Title |
A Study on the Behavior Characteristics of a Tensioning Device of a Catenary System According to the Longitudinal Dynamic Displacement of Railroad Bridge |
Authors |
나연일(Na, Youn-Il) ; 이재봉(Lee, Jae-Bong) ; 김재문(Kim, Jae-Moon) ; 김양수(Kim, Yang-Su) |
DOI |
https://doi.org/10.5370/KIEE.2015.64.10.1517 |
Keywords |
Railroad bridge ; Longitudinal displacement ; Temperature ; Tensioning device ; Stroke movement |
Abstract |
Since electric railroad vehicle pass through repeatedly on the railroad bridge, the dynamic load that causes the change of tension of contact wire affect it constantly. In this paper, we measured the dynamic displacement of the railroad bridges to analyze the effect of tension in the catenary. A result of dynamic measurement of the longitudinal displacement, it's maximum value was 39.9mm which was lower than the primary management criteria 378mm. Also on the based of a maximum temperature, it shows a feature that the longitudinal displacement value increased as temperature rise from April to October. In terms of behavior characteristics of a tensioning device, it was confirmed to be the value of 50mm stroke movement when the temperature changes ±5℃. |