• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Comparative Study of Integer-slot PMSM with Lap Winding and Concentric Winding
Authors 김형우(Hyung-Woo Kim) ; 강도현(Do Hyun Kang) ; 이승창(SungChang Lee) ; 정상용(Sang-Yong Jung) ; 이철균(Cheol-Gyun Lee)
DOI https://doi.org/10.5370/KIEE.2021.70.2.324
Page pp.324-328
ISSN 1975-8359
Keywords Lap Winding; Concentric Winding; Concentrated Winding; Distributed Winding; Number of Slots per Phase per Pole(NSPP); Number of Turns per Phase per Pole(NTPP); THD; Full Pitch; Short Pitch; PMSM; Double Layer; Single Layer
Abstract Winding method differs majorly by number of slots per phase per pole(NSPP). If those of NSPP are integer, Concentrated Winding and Distributed Windings are used. Distributed Windings can be further classified into Lap Winding and Concentric winding according to the pitch distribution of coils. The number of turns and the number of pitch are same between each coil in Lap Winding with Fractional(Short) Pitch. On the other hand, the number of turns in each coil can be different for Concentric Winding maintaining the number of turns per pole. Air-gap Magnetic Motive Force(MMF) distribution appears differently depending on the ratio of turns in each coil. In this paper, the No-load performance of Permanent Magnet Synchronous Motor with Lap Winding and Concentric winding is compared. Winding Factors are calculated to consider the MMF distribution analytically for each winding case. The electromagnetic performance of each winding case is analyzed through 2D Finite Element Analysis(FEA).