• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Wang J., Xu L., Lu Y., Sheng K., Liu W., Chen C., Li Y., Dong B., Song H., 2016, Engineered IrO2@ NiO Core–Shell Nanowires for Sensitive Non-enzymatic Detection of Trace Glucose in Saliva, Analytical Chemistry, Vol. 88, pp. 12346-12353DOI
2 
World Health Organization , 2016, Global report on diabetes, World Health OrganizationGoogle Search
3 
Neutzsky-Wulff A.V., Andreassen K.V., Hjuler S.T., Feigh M., Bay-Jensen A.-C., Zheng Q., Henriksen K., Karsdal M.A., 2012, Future detection and monitoring of diabetes may entail analysis of both β-cell function and volume: How markers of β-cell loss may assist, Journal of Translational Medicine, Vol. 10, pp. 214DOI
4 
Tehrani F., Bavarian B., 2016, Facile and scalable disposable sensor based on laser engraved graphene for electrochemical detection of glucose, Scientific Reports, Vol. 6, pp. 27975DOI
5 
Wang J., 2008, Electrochemical glucose biosensors, Chemical Reviews, Vol. 108, pp. 814-825DOI
6 
Lu L.-M., Zhang L., Qu F.-L., Lu H.-X., Zhang X.-B., Wu Z.-S., Huan S.-Y., Wang Q.-A., Shen G.-L., Yu R.-Q., 2009, A nano-Ni based ultrasensitive nonenzymatic electrochemical sensor for glucose: Enhancing sensitivity through a nanowire array strategy, Biosensors and Bioelectronics, Vol. 25, pp. 218-223DOI
7 
Zhang W., Du Y., Wang M.L., 2015, Noninvasive glucose monitoring using saliva nano-biosensor, Sensing and Bio-Sensing Research, Vol. 4, pp. 23-29DOI
8 
Mastrototaro J.J., 2000, The MiniMed continuous glucose monitoring system, Diabetes Technology and Therapeutics, Vol. 2, No. 1, pp. 13-18Google Search
9 
Wang X., 1981, Introduction to Biosensors, Diss. University of Massachusetts LowellGoogle Search
10 
Bo X., Bai J., Yang L., Guo L., 2011, The nanocomposite of PtPd nanoparticles/onion-like mesoporous carbon vesicle for nonenzymatic amperometric sensing of glucose, Sensors and Actuators, B: Chemical, Vol. 157, pp. 662-668DOI
11 
Zhou Y.-G., Yang S., Qian Q.-Y., Xia X.-H., 2009, Gold nanoparticles integrated in a nanotube array for electrochemical detection of glucose, Electrochemistry Communications, Vol. 11, pp. 216-219DOI
12 
Lee D.-Y., Choi W.-S., Park S.-H., Kwon Y.-S., 2009, Electrochemical detection of self-assembled viologen modified electrode as mediator of glucose sensor, Journal of Electrical Engineering and Technology, Vol. 4, pp. 106-110DOI
13 
Clark Jr., Lyons C., 1962, Electrode systems for continuous monitoring in cardiovascular surgery, Annals of the New York Academy of Sciences, Vol. 102, pp. 29-45DOI
14 
Sternberg R., Barrau M.-B., Gangiotti L., Thévenot D.R., Bindra D.S., Wilson G.S., Velho G., Froguel P., Reach G., 1989, Study and development of multilayer needle-type enzyme-based glucose microsensors, Biosensors, Vol. 4, pp. 27-40DOI
15 
Koudelka M., Gernet S., De Rooij N.F., 1989, Planar amperometric enzyme-based glucose microelectrode, Sensors and Actuators, Vol. 18, pp. 157-165DOI
16 
Gorton L., Bremle G., Csöregi E., Jönsson-Pettersson G., Persson B., 1991, Amperometric glucose sensors based on immobilized glucose-oxidizing enzymes and chemically modified electrodes, Analytica Chimica Acta, Vol. 249, pp. 43-54DOI
17 
Malitesta C., Palmisano F., Torsi L., Zambonin P.G., 1990, Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly (o-phenylenediamine) film, Analytical Chemistry, Vol. 62, pp. 2735-2740DOI
18 
Zhang Y., Wilson G.S., 1993, In vitro and in vivo evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor, Analytica Chimica Acta, Vol. 281, pp. 513-520DOI
19 
Liu S., Ju H., 2003, Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode, Biosensors and Bioelectronics, Vol. 19, pp. 177-183DOI
20 
Park S., Boo H., Chung T.D., 2006, Electrochemical non-enzymatic glucose sensors, Analytica Chimica Acta, Vol. 556, pp. 46-57DOI
21 
Hossain M.F., Park J.Y., 2016, Novel enzymatic glucose biosensor based on distributed electrodes covered with a solvothermal synthesized graphene material and platinum nanoparticles, RSC Advances, Vol. 6, pp. 74453-74461DOI
22 
Rahman M.M., Umar A., Sawada K., 2009, Development of amperometric glucose biosensor based on glucose oxidase co-immobilized with multi-walled carbon nanotubes at low potential, Sensors and Actuators, B: Chemical, Vol. 137, pp. 327-333DOI
23 
Shan C., Yang H., Han D., Zhang Q., Ivaska A., Niu L., 2010, Graphene/AuNPs/chitosan nanocomposites film for glucose biosensing, Biosensors and Bioelectronics, Vol. 25, pp. 1070-1074DOI
24 
Chen C., Xie Q., Yang D., Xiao H., Fu Y., Tan Y., Yao S., 2013, Recent advances in electrochemical glucose biosensors: A review, RSC Advances, Vol. 3, pp. 4473-4491DOI
25 
Toghill K.E., Compton R.G., 2010, Electrochemical non-enzymatic glucose sensors: A perspective and an evaluation, International Journal of Electrochemical Science, Vol. 5, pp. 1246-1301Google Search
26 
Zaidi S.A., Shin J.H., 2016, Recent developments in nanostructure based electrochemical glucose sensors, Talanta, Vol. 149, pp. 30-42DOI
27 
Lin J., Peng Z., Liu Y., Ruiz-Zepeda F., Ye R., Samuel E.L.G., Yacaman M.J., Yakobson B.I., Tour J.M., 2014, Laser-induced porous graphene films from commercial polymers, Nature Communications, Vol. 5, pp. 5714DOI
28 
Wang X., Zhang Y., Zhi C., Wang X., Tang D., Xu Y., Weng Q., Jiang X., Mitome M., Golberg D., Bando Y., 2013, Three-dimensional strutted graphene grown by substrate-free sugar blowing for high-power-density supercapacitors, Nature Communications, Vol. 4DOI
29 
Wang J., Zhang W.-D., 2011, Fabrication of CuO nanoplatelets for highly sensitive enzyme-free determination of glucose, Electrochimica Acta, Vol. 56, pp. 7510-7516DOI
30 
Jena B.K., Raj C.R., 2006, Enzyme-free amperometric sensing of glucose by using gold nanoparticles, Chemistry - A European Journal, Vol. 12, pp. 2702-2708DOI
31 
Shi W., Ma Z., 2010, Amperometric glucose biosensor based on a triangular silver nanoprisms/chitosan composite film as immobilization matrix, Biosensors and Bioelectronics, Vol. 26, pp. 1098-1103DOI
32 
Yuan J., Wang K., Xia X., 2005, Highly ordered platinum-nanotubule arrays for amperometric glucose sensing, Advanced Functional Materials, Vol. 15, pp. 803-809DOI
33 
Liu Y., Teng H., Hou H., You T., 2009, Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode, Biosensors and Bioelectronics, Vol. 24, pp. 3329-3334DOI
34 
Luo L., Zhu L., Wang Z., 2012, Nonenzymatic amperometric determination of glucose by CuO nanocubes-graphene nanocomposite modified electrode, Bioelectrochemistry, Vol. 88, pp. 156-163DOI
35 
Tehrani F., Reiner L., Bavarian B., 2015, Rapid prototyping of a high sensitivity graphene based glucose sensor strip, PLoS ONE, Vol. 10, pp. e0145036DOI
36 
Luo J., Jiang S., Zhang H., Jiang J., Liu X., 2012, A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrode, Analytica Chimica Acta, Vol. 709, pp. 47-53DOI
37 
Kang X., Mai Z., Zou X., Cai P., Mo J., 2007, A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nanotube-modified glassy carbon electrode, Analytical Biochemistry, Vol. 363, pp. 143-150DOI
38 
Molazemhosseini A., Magagnin L., Vena P., Liu C.-C., 2017, Single-use nonenzymatic glucose biosensor based on CuO nanoparticles ink printed on thin film gold electrode by micro-plotter technology, Journal of Electroanalytical Chemistry, Vol. 789, pp. 50-57DOI