• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Terbizan Donna J., Dolezal Brett A., Albano Christian, 2002, Validity of seven commercially available heart rate monitors, Measurement in Physical Education and Exercise Science, Vol. 6, No. 4, pp. 243-247DOI
2 
Spierer David K., et al., 2015, Validation of photo- plethysmography as a method to detect heart rate during rest and exercise, Journal of medical engineering & technology, Vol. 39, No. 5, pp. 264-271DOI
3 
Fallet Sibylle, Jean-Marc Vesin, 2015, Adaptive frequency tracking for robust heart rate estimation using wrist- type photoplethysmographic signals during physical exercise, Computing in Cardiology Conference (CinC), 2015. IEEEDOI
4 
Fallet Sibylle, Jean-Marc Vesin, 2017, Robust heart rate estimation using wrist-type photoplethysmographic signals during physical exercise: an approach based on adaptive filtering, Physiological measurement, Vol. 38, No. 2, pp. 155DOI
5 
Zhang Zhilin, Pi Zhouyue, Liu Benyuan, 2015, TROIKA: A general framework for heart rate monitoring using wrist-type photoplethysmographic signals during intensive physical exercise, IEEE Transactions on Biomedical Engineering, Vol. 62, No. 2, pp. 522-531DOI
6 
Temko Andriy, 2017, Accurate heart rate monitoring during physical exercises using ppg, IEEE Transactions on Biomedical Engineering, Vol. 64, No. 9, pp. 2016-2024DOI
7 
Jarchi Delaram, Casson Alexander J., 2017, Towards photoplethysmography-based estimation of instantaneous heart rate during physical activity, IEEE Transactions on Biomedical Engineering, Vol. 64, No. 9, pp. 2042-2053DOI
8 
Song Jiajia, et al., 2017, A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals, Sensors, Vol. 17, No. 11, pp. 2450DOI
9 
Ram M. Raghu, et al. , 2012, A novel approach for motion artifact reduction in PPG signals based on AS-LMS adaptive filter, IEEE Transactions on Instrumentation and Measurement, Vol. 61, No. 5, pp. 1445-1457DOI
10 
Chan K. W., Zhang Y. T., 2002, Adaptive reduction of motion artifact from photoplethysmographic recordings using a variable step-size LMS filter, Sensors, 2002. Proceedings of IEEE, Vol. 2DOI
11 
Wood Levi B., Asada H. Harry, 2007, Low variance adaptive filter for cancelling motion artifact in wearable photoplethysmogram sensor signals, Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEEDOI
12 
Lee Han-Wook, et al., 2007, The periodic moving average filter for removing motion artifacts from PPG signals, International Journal of Control, Automation, and Systems, Vol. 5, No. 6, pp. 701-706Google Search
13 
Peng Fulai, et al., 2014, Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter, Biomedical engineering online, Vol. 13, No. 1, pp. 50DOI
14 
Lee Boreom, et al., 2011, Adaptive comb filtering for motion artifact reduction from PPG with a structure of adaptive lattice IIR notch filter, Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEEDOI
15 
Liao Ho-En, 2005, Two discrete oscillator based adaptive notch filters (OSC ANFs) for noisy sinusoids, IEEE transactions on signal processing, Vol. 53, No. 2, pp. 528-538DOI