• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Beom An, SungHo Yoon, Sanggoon Lee, JeongTae Kim, YeonHa Jeong, 2020, A Study on the Factors Effecting of Partial Discharge Pattern Recognition, Proceedings of the Korean Electrical Society Conference, pp. 1537-1538Google Search
2 
Min-Woo Chae1, 2021, Application of Ultrasonic Measurement and Deep Learning Technique for Partial Discharge Diagnosis, Journal of Institute of Control, Robotics and Systems, Vol. 27, No. 11, pp. 809-814Google Search
3 
A. Gemant, W. Philippoff, 1932, Die Funkenstrecke mit Vorkondensator, Zeitschrift für Technische Physik, Vol. 13, No. 9, pp. 425-430Google Search
4 
W. Böning, 1963, Luftgehalt und Luftspaltverteilung geschichteter Dielektrika I. Untersuchung der Entladungen in einzelnen Luftspalten bei äußerem Wechselfeld, Electrical Engineering (Archiv für Elektrotechnik), Springer Berlin / Heidelberg, ISSN 0948-7921 (Print) 1432-0487 (Online), Vol. 48, No. 1Google Search
5 
A. Pedersen, 1987, Partial discharges in voids in solid dielectrics. An alternative approach, Conference on Electrical Insulation & Dielectric Phenomena, Gaithersburg, MD, USADOI
6 
L. E. Lundgaard, 1992, Partial discharge. part XIII. Acoustic partial discharge detection - fundamental considerations, IEEE Electrical Magazine, Vol. 8, No. 4, pp. 1149-1163DOI
7 
Hee-Ro Kwak, Dong-Zoon Lee, 2000, A Study on the Predictive Diagnosis of the Cable Joint Using Ultrasonic Technique, Journal of the korean institute of llluminating and Electrical installation Engineers vol, Vol. 14, No. 6, pp. 78-84Google Search
8 
M. Kunicki, A. Cichon, 2018, Application of a phase resolved partial discharge pattern analysis for acoustic emission method in high voltage insulation systems diagnostics, Archives of Acoustics, Vol. 43, No. 2, pp. 235-243Google Search
9 
X.-D. Huang, C.-Z. Fu, L. Su, D.-D. Zhao, R. Xiao, Q.-Y. Lu, W.-R. Si, 2019, Research on a general fast analysis algorithm model for PD acoustic detection system: the software development, International Conference on Measuring Technology and Mechatronics Automation, Qiqihar, China, pp. 671-675DOI
10 
Y. H. M. Thayoob, S. K. Ahmed, C. C. Piau, C. Y. Ping, Y. Balasubramaniam, 2015, Characterization of phase resolved partial discharge waveforms from instrument transformer using statistical signal processing technique, IEEE Conference on Signal and Image Processing Applications, pp. 355-360DOI
11 
Ji-Man Park, Ga-Ram Han, 2017, An Analysis of Partial Discharge Characteristics using 22.9 kV CNCV Cable with Artificial defects, Journal of the Korean Institute of IIIuminating and Electrical Installation Engineers, Vol. 31, No. 12, pp. 78-85Google Search
12 
S. Tokunaga, T. Tsurusaki, Y. Z. Arief, S. Ohtsuka, T Mizuno, M Hikita, 2003, Partial discharge characteristics till, breakdown for XLPE cable joint with an artificial defect, Proceedings 7th International Conference on Applications of Dielectric MaterialsDOI
13 
A. Cavallini, G. C. Montanari, A. Contin, F. Pulletti, 2003, A new approach to the diagnosis of solid insulation systems based on PD signal inference, IEEE Electrical Insulation Magazine, Vol. 19, No. 2, pp. 23DOI
14 
Liu Zhiheng, Liu Xiuling, Zhang Zhaoyan, Zhang Wenna, Yao Jianquan, Research on Optical Fiber Sensor Localization Based on the Partial Discharge Ultrasonic Characteristics in Long-Distance XLPE Cables, IEEE ACCESS : 184744-184751.DOI
15 
Seung-Gyu kim, Sang-Woo Lee, Kyung-Chul Gu, Chung- Nyen Kim, In-Sik Kim, Kwang-Sik Lee, 1999, Detection of Ultrasonic Wave Signals Associated with Partial Dischare in XLPE, Journal of the korean institute of llluminating and Electrical installation Engineers, Vol. proceedings of the fall conference, pp. 136-140Google Search