References

1 
Y. Huo, G. Prasad, L. Atanackovic, L. Lampe, V. C. Leung, "Cable diagnostics with power line modems for smart grid monitoring," IEEE Access, vol. 7, pp. 60206-60220, 2019. DOI
2 
M. S. Lim, K. H. Park, G. H. Kim, Y. S. Seo, J. S. Lim, "Conformity assessment for VLF tan $\delta$-based cable degradation diagnosis evaluation," Trans. Korean Inst. Electr. Eng., vol. 74, no. 12, pp. 2273-2280, 2025. Google Search
3 
M. Buhari, V. Levi, S. K. E. Awadallah, "Modelling of ageing distribution cable for replacement planning," IEEE Trans. Power Syst., vol. 31, no. 5, pp. 3996-4004, 2015. Google Search
4 
M. Choudhary, M. Shafiq, I. Kiitam, A. Hussain, I. Palu, P. Taklaja, "A review of aging models for electrical insulation in power cables," Energies, vol. 15, no. 9, pp. 3408, 2022. DOI
5 
C. N. Sanniyati, Y. Z. Arief, Z. Adzis, N. A. Muhamad, M. H. Ahmad, M. A. B. Sidik, K. Y. Lau, "Water tree in polymeric cables: a review," Malaysian J. Fundam. Appl. Sci., vol. 12, no. 1, pp. 12-21, 2016. DOI
6 
A. Abideen, F. Mauseth, Ø. L. Hestad, H. Faremo, "Review of water treeing in polymeric insulated cables," vol. 27, no. 1, 2022. Google Search
7 
E. Ildstad, "Challenging defects of high voltage insulation systems," pp. 1-13, 2019. Google Search
8 
J. C. Fothergill, "The coming of age of HVDC extruded power cables," pp. 124-137, 2014. Google Search
9 
I. Pleşa, P. V. Noţingher, C. Stancu, F. Wiesbrock, S. Schlögl, "Polyethylene nanocomposites for power cable insulations," Polymers, vol. 11, no. 1, pp. 24, 2018. DOI
10 
W. Wang, X. Yan, S. Li, L. Zhang, J. Ouyang, X. Ni, "Failure of submarine cables used in high-voltage power transmission: Characteristics, mechanisms, key issues and prospects," IET Gener. Transm. Distrib., vol. 15, no. 9, pp. 1387-1402, 2021. DOI
11 
R. Sarathi, A. Nandini, M. Danikas, "Understanding electrical treeing phenomena in XLPE cable insulation adopting UHF technique," J. Electr. Eng., vol. 62, no. 2, pp. 73, 2011. DOI
12 
"IEEE guide for field testing of shielded power cable systems using very low frequency (VLF) (less than 1 Hz)," IEEE Std 400.2-2024, IEEE, New York, NY, USA, 2024. Google Search
13 
P. Werelius, P. Tharning, R. Eriksson, B. Holmgren, U. Gafvert, "Dielectric spectroscopy for diagnosis of water tree deterioration in XLPE cables," IEEE Trans. Dielectr. Electr. Insul., vol. 8, no. 1, pp. 27-42, 2001. DOI
14 
"Power cables with extruded insulation and their accessories for rated voltages from 1 kV up to 30 kV – Part 2: Cables for rated voltages from 6 kV up to 30 kV," IEC 60502-2, IEC, Geneva, Switzerland, 2014. Google Search
15 
M. Baur, "Testing and diagnostic with dissipation factor (tan$\delta$) measurement at 0.1 Hz on distribution cables," pp. 1-5, 1996. Google Search
16 
S. M. Kim, S. G. Kim, N. K. Cho, I. R. Roh, J. Lim, "A numeric estimation of the aging processing of polymeric MV cables applying three dimensional assessment of VLF tan$\delta$," vol. 15, pp. 1-8, 2015. Google Search
17 
G. H. Kim, Y. S. Seo, J. S. Lim, in press, "A statistical study on insulation degradation using very low frequency diagnostic standards," 2026. Google Search
18 
G. H. Kim, K. H. Park, M. S. Lim, Y. S. Seo, J. S. Lim, "Comparison of VLF tan$\delta$ degradation diagnosis criteria for underground distribution cables," pp. 1987-1988, 2025. Google Search
19 
S. A. Ryu, M.S. thesis, Dept. of Marine Electronics, Communication and Computer Eng., "Evaluation method of VLF tan$\delta$ factor combination for MV underground cable diagnosis," Mokpo Nat. Maritime Univ., Mokpo, South Korea, 2024. Google Search