Title |
Comparison of Electromagnetic Characteristics of Wound Field Synchronous Motor According to Pole Slot Combination |
Authors |
조재훈(Jae-Hoon Cho) ; 윤한준(Han-Joon Yoon) ; 전성배(Sung-Bae Jun) ; 정상용(Sang-Yong Jung) |
DOI |
https://doi.org/10.5370/KIEE.2023.72.1.65 |
Keywords |
Efficiency; Power Factor (PF); Pole Slot Combination; Rare-Earth Magnet Free; Total Harmonic Distortion (THD); Wound Field Synchronous Motor (WFSM) |
Abstract |
This paper analyzes the electromagnetic characteristics of wound field synchronous motor (WFSM) for home appliances according to pole slot combination. The analyzed factors are output torque, total harmonic distortion (THD) of back-EMF, cogging torque, efficiency and power factor (PF) which should be considered when designing motors. The pole slot combinations are selected with same number of slots per pole per phase (NSPP) of prototype interior permanent magnet synchronous motor (IPMSM). Because the electromagnetic performances show specific tendencies depending on the number of poles and each performance tends to be different, this study can be a reference in determining pole slot combinations of WFSM. |