• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
Z. Zhuo, N. Zhang, J. Yang, C. Kang, C. Smith, M.J. O'Malley, and B. Kroposki, “Transmission Expansion Planning Test System for AC/DC Hybrid Grid With High Variable Renewable Energy Penetration,” IEEE trans. on power systems, vol. 35, no. 4, pp. 2597-2608, 2020.DOI
2 
M. Brenna, G. C. Lazaroiu, and E. Tironi, “High Power Quality and DG Integrated Low Voltage dc Distribution System,” in Proc. IEEE Power Engineering Society General Meeting 2006, June 18-22, Montreal, Canada, pp. 6, 2006.DOI
3 
T. Wang, A. Monti, R. Goldbeck, and R. W. De Doncker, “Voltage Selection and Personal Safety in Low Voltage Direct Current Networks at Customer End,” 2018 IEEE PES Innovative Smart Grid Technologies Conf., 2018.DOI
4 
D. W. Kim. Y. B. Lim. S. I. Lee, M. I. Choi, and H. W. Moon, “Protection Techniques Against Electric Shock in Low Voltage DC Grounding Systems Depending on the Analysis of Earth Fault Current Paths,” The transactions of The Korean Institute of Electrical Engineers, vol 65, no. 1, pp. 232-238, 2016.DOI
5 
S. Wang, H. Li, Q. Liu, W. Su, and C. Wang, “Research on the Requirements for the Break Time of DC-RCD Under Different Voltage Levels and Grounding Modes in LVDC System,” 2020 IEEE 4th Conference on Energy Internet and Energy System Integration (EI2), 2020.DOI
6 
Y. S. Oh, J. Han, G. H. Gwon, D. U. Kim, C. H. Noh, T. H. Jung, and C. H. Kim, “Analysis of Human Safety and System Effect according to Grounding Scheme in LVDC Distribution System,” The Transactions of the Korean Institute of Electrical Engineers vol. 63, no. 5, pp. 608-614, 2014.DOI
7 
KESCO, “A Statistical Analysis on the Electrical Accident,” 2023.URL
8 
IEC, “IEC 60479-1,” 2018.URL
9 
IEC, “IEC 60479-2,” 2019.URL
10 
KEA, “Korea Electro-technical Code,” 2023.URL
11 
IEC, “IEC 60364-4-41,” 2005.URL
12 
IEC, “IEC 60755,” 2022.URL
13 
IEC, “IEC TS 63053,” 2017.URL
14 
D. S. Shin, M. H. Lee, Y. M. Koo, J. H. Jung, K. D. Kim, J. C. Lee, and H. S. Kim, “Study on improving the installation of earth leakage circuit breakers to protect people from electric shock in hazardous locations,” winter conference of the Korean Society of Safety, pp. 136-142, 2002.1.URL
15 
KATS, “KS C IEC 61200-413,” 1996.URL
16 
D. H. Kim, S. C. Kim, E. S. Kim, C. O. Kim, D. H. Lee, S. I. Lee, J, H. Jung, C. S. Chio, S. H. Kang, and S. G. Jo, “Electrical Safety Engineering,” Donghwa, 2016.URL
17 
T. Takehiko, “Electric shock protection in Japan,” Joulnal of Electrical World, vol. 365, pp. 1-19, 2007.URL
18 
T. Takehiko, “Electrical safety in the house,” Joulnal of Electrical World, vol. 453, pp. 18-30, 2014.URL
19 
J. S. Park, and Y. R. Choi, “DC Earth Leakage Breaker for Protecting Human Body from Electric Shock in LVDC System for the End User’s,” The Transactions of the Korean Institute of Electrical Engineers, vol. 72, no. 11, pp. 1512~ 1519, 2023.URL