• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid

References

1 
G. A. Mensah, J. B. Croft, and W. H. Giles, “The heart, kidney, and brain as target organs in hypertension,” Cardiology clinics 20, no. 2, pp.225-247, 2002.DOI
2 
"Hypertension", <World Health Organization>, <https://www.who.int/news-room/fact-sheets/detail/hypertension>, (Access Date 2024.03.12.)URL
3 
B. V. Scheer, A. Perel, and U. J. Pfeiffer, “Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine,” Critical care, vol. 6, no. 3, pp. 1-7, 2002.DOI
4 
J. Penaz, “Photoelectric measurement of blood pressure, volume and flow in the finger,” In Digest of the 10th international conference on medical and biological engineering-Dresden, vol. 104, 1973.URL
5 
R. D. Boehmer, “Continuous, real-time, noninvasive monitor of blood pressure: Peňaz methodology applied to the finger,” Journal of clinical monitoring, vol. 3, pp. 282-287, 1987.DOI
6 
S. Rastegar, H. GholamHosseini, and A. Lowe, “ Non-invasive continuous blood pressure monitoring systems: current and proposed technology issues and challenges,” Physical and Engineering Sciences in Medicine, vol. 43, pp. 11-28, 2020.DOI
7 
J. Liu, H. Cheng, C. H. Chen, S. H. Sung, J. O. Hahn, and R. Mukkamala, “Model-based oscillometric blood pressure measurement: Preliminary validation in humans,” In 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 1961-1964, 2014.DOI
8 
J. Liu, H. M. Cheng, C. H. Chen, S. H. Sung, M. Moslehpour, J. O. Hahn, and R. Mukkamala, “Patient-specific oscillometric blood pressure measurement,” IEEE Transactions on Biomedical Engineering, vol. 63, no. 6, pp. 1220-1228, 2015.DOI
9 
J. Liu, H. M. Cheng, C. H. Chen, S. H. Sung, J. O. Hahn, and R. Mukkamala, “Patient-specific oscillometric blood pressure measurement: validation for accuracy and repeatability,” IEEE journal of translational engineering in health and medicine, vol. 5, pp. 1-10, 2016.DOI
10 
A. Chandrasekhar, M. Yavarimanesh, J. O. Hahn, S. H. Sung, and R. Mukkamala, “Formulas to explain popular oscillometric blood pressure estimation algorithms,” Frontiers in physiology, vol. 10, p. 1415, 2019.DOI
11 
V. Dhamotharan, A. Chandrasekhar, H. M. Cheng, C. H. Chen, S. H. Sung, C. Landry, J. O. Hahn, A. Mahajan, S. G. Shroff, and R. Mukkamala, “Mathematical modeling of oscillometric blood pressure measurement: A complete, reduced oscillogram model,” IEEE Transactions on Biomedical Engineering, vol. 70, no. 2, pp. 715-722, 2022.DOI
12 
G. Drzewiecki, V. Bansal, E. Karam, R. Hood, and H. Apple, “Mechanics of the occlusive arm cuff and its application as a volume sensor,” IEEE transactions on biomedical engineering, vol. 40, no. 7, pp. 704-708, 1993.DOI
13 
P. D. Baker, D. R. Westenskow, and K. Kück, “Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure,” Medical and biological engineering and computing, vol. 35, pp. 271-278, 1997.DOI
14 
G. Drzewiecki, R. Hood, and H. Apple, “Theory of the oscillometric maximum and the systolic and diastolic detection ratios,” Annals of biomedical engineering, vol. 22, pp. 88-96, 1994.DOI
15 
G. J. Langewouters, K. H. Wesseling, and W. J. A. Goedhard, “The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model,” Journal of biomechanics, vol. 17, no. 6, pp. 425-435, 1984.DOI
16 
M. P. McLaughlin, “A compendium of common probability distributions,” Michael P. McLaughlin, pp. 11-12, 2016.URL
17 
M. Freithaler, A. Chandrasekhar, V. Dhamotharan, C. Landry, S. G. Shroff, and R. Mukkamala. “Smartphone-Based Blood Pressure Monitoring via the Oscillometric Finger Pressing Method: Analysis of Oscillation Width Variations Can Improve Diastolic Pressure Computation.” IEEE Transactions on Biomedical Engineering, vol. 70, no. 11, pp. 3052-3063, 2023.DOI
18 
X. R. Ding, Y. T. Zhang, J. Liu, W. X. Dai, and H. K. Tsang, “Continuous cuffless blood pressure estimation using pulse transit time and photoplethysmogram intensity ratio,” IEEE Transactions on Biomedical Engineering, vol. 63, no. 5, pp. 964-972, 2015.DOI